Contents
- 1 Hazardous Warnings
- 3 Technical Support
- 4 Introduction
- 4.1 ESP-TM2 Controller Features
- 4.1.1 WiFi Enabled
- 4.1 ESP-TM2 Controller Features
- 5 Installation
- 5.1 Mount Controller
- 5.2 Wiring Connections
- 5.2.1 Connect Valves
- 5.2.2 Connect Master Valve (optional)
- 5.2.3 Connect Pump Start Relay (optional)
- 5.2.4 Connect Rain/Freeze Sensor (optional)
- 5.2.5 Connect Custom Wiring (optional)
- 6 Controls and Indicators
- 7 Basic Programming
- 7.1 Set Date and Time
- 7.2 Set Watering Start Times
- 7.3 Set Station Run Times
- 7.4 Set Watering Days
- 7.4.1 Custom Days of the Week
- 8 Manual Watering Options
- 8.1 Test All Stations
- 8.2 Run a Single Station
- 8.3 Run a Single Program
- 9 Normal Operation
- 9.1 AUTO RUN
- 9.2 OFF
- 10 Advanced Programming
- 10.1 Odd or Even Calendar Days
- 10.2 Cyclic Days
- 10.3 Rain Sensor
- 10.4 Seasonal Adjust
- 10.5 Delay Watering
- 10.6 Permanent Days Off
- 11 Special Features
- 12 Options
- 12.1 Reset Button
- 12.2 Accessories
- 13 Troubleshooting
- 13.1 Watering Issues
- 13.2 Automatic and/or Manual Watering will not start
- 13.3 Excessive watering
- 13.4 Electrical Issues
- 13.5 Display is blank.
- 13.6 Display is frozen and controller will not accept programming.
- 14 Certifications
- 15 Safety Information
- 16 Rain Bird ESP-TM2 on the Web
- 17 Videos
- 17.1 Rain Bird ESP-TM2 Controller: Manual Watering Options Video by Rain Bird
- 17.2 Rain Bird ESP-TM2 Controller: Basic Programming Video by Rain Bird
- 17.3 Rain Bird ESP-TM2 Controller: Advanced Programming Video by Rain Bird
- 17.4 Rain Bird ESP-TM2 Controller: Installation Video by Rain Bird
- 18 Documents / Resources
- 18.1 References
- 18.2 Download manual
Rain Bird ESP-TM2 Manual
LNK™ Ready
Hazardous Warnings
Indicates a hazardous situation that, if not avoided, could result in death or serious injury.
Indicates a hazardous situation that, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates information considered important, but not hazard-related (e.g., messages relating to property damage).
SAFETY INSTRUCTIONS
Specific safety-related instructions or procedures are described.
Symbols & User Operation
NUMBERS define a series of steps for the user to follow in order to operate the controller.
NOTE: Notifies the user of important operating instructions related to controller functionality, installation or maintenance.
REPEAT: Indicates that a repetition of previous steps or actions may be required for further operation, or to complete a process.
Technical Support
Questions?
For help setting up and operating the Rain Bird ESP-TM2 Controller, scan the QR code to visit
www.rainbird.com/esptm2
Additional user documentation is available under the Manuals & Literature tab, including:
- User Manual (this document)
- Quick Reference Guide
- Programming Guide
- Foreign Language Support
To learn more about Rain Bird irrigation systems and our Rain Bird Academy training programs, visit: www.rainbirdservices.com/training
To see instructional videos for the ESP-TM2, visit www.youtube.com/
Introduction
ESP-TM2 Controller Features
Feature | Description |
Maximum Stations | 12 |
Simultaneous Stations | 1 plus master valve |
Start Times | 4 |
Programs | 3 |
Program Cycles | Custom Days, Odd, Even and Cyclic |
Permanent Days Off | Per program |
Master Valve Control | On/Off per station |
Rain Delay | Supported |
Rain/Freeze Sensor | Supported |
Rain Sensor Control | Global or by station |
Seasonal Adjust | Global or by program |
Manual Station Run | Yes |
Manual Program Run | Yes |
Manual Test All Stations | Yes |
Station Advance | Yes |
Short Detect | Yes |
Delay Between Stations | Yes |
Accessory Port | Yes (5 pin) |
Save & Restore Programming | Yes |
WiFi Compatible | Yes - with LNK™ WiFi Module |
WiFi Enabled
The LNK™ WiFi Module allows remote connection to a Rain Bird ESP-TM2 Controller using an Apple iOS or Android compatible smart device. The mobile application allows remote access and configuration of one or more irrigation controllers.
For more information on the LNK™ WiFi Module and the value this product can provide for your ESP-TM2 controller, please visit: http://wifi-pro.rainbird.com
LNK™ WiFi Module (sold separately)
Manage Sites Remotely
Installation
Mount Controller
NOTE: Choose a suitable mounting location close to a 230VAC wall outlet.
- Drive a mounting screw into the wall, leaving an 1/8 inch gap between the screw head and the wall surface (use the supplied wall anchors if necessary), as shown.
- Locate the keyhole slot on back of the controller unit and hang it securely on the mounting screw.
- Remove the wiring bay cover on the lower part of the controller unit, and drive a second screw through the open hole inside the controller and into the wall, as shown.
Wiring Connections
Connect Valves
- Route all field wires through the opening at the bottom of the unit, or through the knock-out in back of the unit. Attach conduit if desired, as shown.
Do not route valve wires through the same opening as power wires. - Connect one wire from each valve to one of the numbered station terminals (1-12) on the controller, as shown.
- Connect a field common wire (C) to the common terminal (C) on the controller. Then connect the remaining wire from each valve to the field common wire, as shown.
NOTE: The ESP-TM2 controller supports one valve solenoid per station terminal.
Connect Master Valve (optional)
- Connect a wire from the master valve (M) to the master valve terminal (M) on the controller. Then connect the remaining wire from the master valve to the field common wire, as shown.
Connect Pump Start Relay (optional)
The ESP-TM2 can control a pump start relay, to turn the pump on and off as needed.
- Connect a wire from the pump start relay (PSR) to the master valve terminal (M) on the controller. Then connect another wire from the pump start relay to the field common wire, as shown.
- To avoid the possibility of damage to the pump, connect a short jumper wire from any unused terminal(s) to the nearest terminal in use, as shown.
NOTICE
The ESP-TM2 controller DOES NOT provide power for a pump. The relay must be wired according to manufacturer instructions.
Only the following Rain Bird pump start relay models are compatible with the ESP-TM2:
Description | Model # | Volts |
Universal Pump Relay | PSR110IC | 110V |
Universal Pump Relay | PSR220IC | 220V |
NOTE: Connection to pump and external power not shown. Refer to pump installation instructions.
Connect Rain/Freeze Sensor (optional)
The ESP-TM2 controller can be set to obey or ignore a rain sensor.
Refer to the Rain Sensor section under Advanced Programming.
- Remove the yellow jumper wire from the SENS terminals on the controller.
NOTICE
Do not remove the yellow jumper wire unless connecting a rain sensor. - Connect both rain sensor wires to the SENS terminals, as shown.
Do not route the rain sensor wires through the same opening as the power wiring
NOTE: Rain Bird controllers are only compatible with normally closed rain sensors.
NOTE: For wireless rain/freeze sensors, refer to installation instructions for sensor.
Connect Custom Wiring (optional)
If desired, the provided 230 volt power cord can be removed and replaced with a custom wiring.
DO NOT plug in the transformer or connect external power until you have completed and checked all wiring connections.
Electric shock can cause severe injury or death. Make sure power supply is turned OFF before connecting power wires.
- Locate the transformer wiring compartment in the lower left corner of the controller unit. Use a screwdriver to remove the cover and expose the transformer connection wires.
- Route the three external power source wires through the conduit opening at the bottom of the unit and into the wiring compartment.
- Connect the external power source wires (two power and one ground) to the transformer connection wires inside the wiring compartment.
Ground wire must be connected to provide electrical surge protection. Permanently mounted conduit shall be used for connecting main voltage to the controller
NOTE: Use either the provided wire nuts or the installed connector for this step.
- Verify that all wiring connections are secure, then replace the wiring compartment cover and secure it with the screw.
DO NOT apply power until you have completed and checked all wiring connections.
POWER WIRING CONNECTIONS 230 VAC (International)
Brown supply wire (hot) to the brown transformer wire labeled with "L"
Blue supply wire (neutral) to the blue transformer wire labeled with "N"
Green-with-yellow-stripe supply wire (ground) to the green-with-yellow-stripe transformer wire
Controls and Indicators
Turn the dial to select programming features.
- OFF
Disables automatic irrigation. - MANUAL STATION
Start watering any or all stations immediately. - SEASONAL ADJUST
Adjust Run Times from 5% up to 200%. - SENSOR
Set controller to obey or ignore a rain sensor. - AUTO RUN
Watering occurs automatically. - DATE/TIME
Set the current Date and Time. - PROGRAM SELECT BUTTON
Select Program A, B or C. - – / + BUTTONS
Adjust program settings. - BACK/NEXT BUTTONS
Select programming options. - START TIMES
Set up to 4 Start Times per program. - RUN TIMES
Set Run Times for each program. - RUN DAYS
Set watering day options for each program.
Basic Programming
Set Date and Time
Turn the dial to DATE/TIME.
- Press
or
to select the setting to change.
- Press
or
to change the setting value.
- Press and hold
or
to accelerate adjustments.
To change the time format (12 hour or 24 hour): - With MINUTES blinking, press
.
- Press
or
to select the desired time format, then press
to return to the time setting.
Set Watering Start Times
Up to four Start Times are available for each program.
Turn the dial to START TIMES.
- Press Program Select to choose the desired Program (if necessary).
- Press
or
to select an available Start Time.
- Press
or
to set the selected Start Time (ensure the AM/PM setting is correct).
- Press
to set additional Start Times.
Set Station Run Times
Run Times can be set from one minute up to six hours.
Turn the dial to RUN TIMES.
- Press Program Select to choose the desired Program (if necessary).
- Press
or
to select a Station.
- Press
or
to set the Run Time for the selected Station.
- Press
to set additional Station Run Times.
NOTE: Rain Bird recommends that the maximum irrigation zone cycle time be less than the time required for runoff to begin and that there be adequate soak time before the next irrigation cycle of that same zone begins again.
Set Watering Days
Custom Days of the Week
Set watering to occur on specific days of the week.
Turn the dial to RUN DAYS.
- Press Program Select to choose the desired Program (if necessary).
- Press
or
to set the selected (blinking) day as either ON or OFF, and to automatically move to the next day.
- You can press
or
at any time to move the cursor to the previous or next day.
NOTE: If Sunday is selected,
will enter and activate Cyclic Watering (see the Advanced Programming section). If this is not desired, press the
button to return to watering by Custom Days.
Manual Watering Options
Test All Stations
Start watering immediately for all programmed stations.
Turn the dial to MANUAL STATION.
- Press
or
to set a Run Time.
- Press and hold
or turn the dial to AUTO RUN to start manual station test.
Run a Single Station
Start watering immediately for a single station.
Turn the dial to MANUAL STATION.
- Press
to display the MANUAL STATION screen.
- Press
or
to select a Station.
- Press
or
to set a Run Time.
- Press and hold
or turn the dial to AUTO RUN to start the selected Station.
Run a Single Program
Start watering immediately for one program.
Turn the dial to AUTO RUN.
- Press Program Select to choose the desired Program (if necessary).
- Press and hold
to start the selected Program.
During Manual Watering:
The display shows a blinking sprinkler symbol, the active Station Number or Program, and the Remaining Run Time.
- To cancel manual watering, turn the dial to OFF for three seconds until the screen shows OFF.
Normal Operation
AUTO RUN
During watering, the display shows a blinking sprinkler symbol, the current Program and the Remaining Run Time.
OFF
Turn the dial to OFF to stop automatic irrigation or to cancel all active watering immediately.
NOTICE
Watering will NOT occur if the controller remains in the OFF position.
Advanced Programming
Odd or Even Calendar Days
Set watering to occur on all ODD or EVEN calendar days.
Turn the dial to RUN DAYS.
- Press Program Select to choose the desired Program (if necessary).
- Press and hold
and
at the same time until ODD or EVEN is displayed.
Cyclic Days
Set watering to occur at specific intervals, such as every 2 days, or every 3 days, etc.
Turn the dial to RUN DAYS.
- Press Program Select to choose the desired Program (if necessary).
- On the Custom Days screen, press
until the Cyclic screen is displayed (after SUN).
- Press
or
to set the desired DAY CYCLE, then press
.
- Press
or
to set the DAYS REMAINING before the cycle begins. The NEXT watering day updates on the display to indicate the day that watering will start as shown.
Rain Sensor
Set the controller to obey or ignore a rain sensor.
When set to ACTIVE, automatic irrigation will be suspended if rainfall is detected. When set to BYPASS all programs will ignore the rain sensor.
Turn the dial to SENSOR.
- Press
or
to select ACTIVE (obey) or BYPASS (ignore).
Obey sensor
Ignore sensor
Rain detected (flashing)
NOTE: See Special Features to set Rain Sensor Bypass by Station.
Seasonal Adjust
Increase or decrease program run times by a selected percentage (5% to 200%).
Example: If the Seasonal Adjust is set to 100% and the station Run Time is programmed for 10 minutes, the station will run for 10 minutes. If the Seasonal Adjust is set to 50%, the station will run for 5 minutes.
Turn the dial to SEASONAL ADJUST.
- Press
or
to increase or decrease the global percentage setting.
- To adjust an individual Program, press Program Select to choose the desired Program (if necessary).
Delay Watering
Suspend watering for up to 14 days.
Turn the dial to AUTO RUN, then press and hold
.
- Press
or
to set the DAYS REMAINING. The next watering day will update on the display to indicate when watering will resume.
- To cancel a Rain Delay, set the DAYS REMAINING back to 0.
NOTE: When the delay expires, automatic irrigation resumes as scheduled.
Permanent Days Off
Prevent watering on selected days of the week (for Odd, Even or Cyclic programming only).
Turn the dial to RUN DAYS.
- Press Program Select to choose the desired Program (if necessary).
- Press and hold Program Select.
- Press
to set the selected (blinking) day as a Permanent Day Off or press
to leave the day ON.
Special Features
- Turn the dial to the desired position.
- Press and hold
and
at the same time.
- SET INTERSTATION DELAY
A station delay (from 1 second to 9 hours) ensures that a valve has completely closed before the next one opens. - RESET TO FACTORY DEFAULTS
All programmed schedules will be erased. - SET RAIN SENSOR BYPASS BY STATION
Tells a station to obey or ignore a rain sensor. - SAVE PROGRAMMING
- RESTORE PROGRAMMING
- SET MASTER VALVE BY STATION
Allows a station to be controlled by a master valve or pump start relay. - SET TO ODD, EVEN OR CYCLIC WATERING
See Advanced Programming.
Options
Reset Button
If the controller is not working properly, you can try pressing RESET.
- Insert a small tool such as a paper clip, into the access hole and press until the controller is reset. All previously programmed watering schedules will remain stored in memory.
Accessories
A 5 pin accessory port is available for Rain Bird approved external devices, including:
- LNK™ WiFi Module
- LIMR Receiver Quick Connect harness
Troubleshooting
Watering Issues
Problem | Possible Cause | Possible Solution |
![]() | Water supply issue. | Verify there is no disruption to the main water line and that all other water supply lines are open and functioning. |
Wiring is loose, not properly connected or damaged. | Check that wiring is securely connected at the controller and in the field. Check for damage and replace if necessary. Check wiring connections and replace with watertight splice connectors if needed. | |
Automatic and/or Manual Watering will not start | Connected rain sensor may be activated. | Let the rain sensor dry out or else disconnect it from the controller terminal block and replace it with a jumper wire connecting the two SENS terminals. |
Jumper wire connecting the two SENS terminals may be missing or damaged. | Jumper the two SENS terminals on the controller terminal block by connecting them with a short length of 14 to 18 gauge wire. | |
Solenoid or master valve is shorted. | Confirm short message on the display. Correct the issue in the wiring. Clear the message by testing watering at the shorted valve or by pressing the ![]() | |
Excessive watering | Programs may have multiple start times that were set unintentionally | Programs (A, B or C) only require a single start time in order to run. Separate start times are not required for each valve. |
Electrical Issues
Problem | Possible Cause | Possible Solution |
Display is blank. | Power not reaching the controller. | Verify the main AC power supply is securely plugged in or connected and working properly. |
Verify the orange power supply wires are connected to the controller "24 VAC" terminals. | ||
Display is frozen and controller will not accept programming. | An electrical surge may have interfered with the controller's electronics. | Unplug the controller for 2 minutes, then plug it back in. If there is no permanent damage, the controller should accept programming and resume normal operation. |
Press and release the RESET button. |
Certifications
EU Declaration of Conformity
Rain Bird Corporation hereby declares that the following irrigation controllers are EU compliant.
- The products submitted meet the requirements of IP24.
- The object of the declaration described above is in conformity with the relevant Union Harmonization Legislation:
Product name: ESP-TM2 Irrigation Controller
Model #: ESP-TM2
Standards to which conformity is declared:
2014/30/EU EMC Directive (EMC) - EN 55014-1:2006 + A2:2011
- EN 55014-2:1997 + A1:2001 + A2:2008
2014/35/EU Low Voltage Directive (LVD) - EN 60335-1:2012 + A11:2014 + AC:2014
- EN 62233:2008+AC: 2008
2011/65/EU RoHS Directive - EN 50581:2012
Signature:
Full name: Ryan L. Walker
Position Director
Date: March 21, 2018
Place: San Diego, CA USA
Rain Bird Corporation
970 W. Sierra Madre
Azusa, California 91702,
U.S.A.
626-963-9311
Rain Bird International,
Inc. 1000 West Sierra
Madre Azusa, CA 91702,
U.S.A.
Ph: (626) 963-9311
Fax: (626) 852-7343
Rain Bird Europe
240 Rue René Descartes
Batiment A PARC
CLAMAR
BP 40072
13792 AIX EN PROVENCE
CEDEX 3 FRANCE
Waste Electrical and Electronic Equipment (WEEE)
As a hardware manufacturer, Rain Bird has met its national obligations to the EU WEEE Directive by registering in those countries to which Rain Bird is an importer. Rain Bird has also elected to join WEEE Compliance Schemes in some countries to help manage customer returns at end of life.
Safety Information
Special precautions must be taken when valve wires (also known as station or solenoid wires) are located adjacent to, or share a conduit with other wires, such as those used for landscape lighting, other "low voltage" systems or other "high voltage" power.
Separate and insulate all conductors carefully, taking care not to damage wire insulation during installation. An electrical "short" (contact) between the valve wires and another power source can damage the controller and create a fire hazard.
All electrical connections and wiring runs must comply with local building codes. Some local codes require that only a licensed or certified electrician can install power. Only professional personnel should install the controller. Check your local building codes for guidance.
If the supply cord of an outdoor controller is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
If the supply cord of an indoor controller is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
If the electrical cord for models ESP-TM2 AUS is damaged, it needs to be replaced with the following:
Flexible supply cord H05VV-F
Minimum wire size of 0.75mm^2 (18 AWG). For Direct Connect wiring, the minimum wire size is 0.75mm^2 (18 AWG).
Outdoor controller shall be permanently connected to fixed wiring by a flexible cord, and have a cord anchorage. The cord anchorage shall relieve conductors from strain, including twisting, at the terminals and protect the insulation of the conductors from abrasion.
NOTICE
Use only Rain Bird approved accessory devices. Changes or modifications not expressly approved by Rain Bird could void the user's authority to operate the equipment. Unapproved devices may damage the controller and void the warranty. For a list of compatible devices go to: www.rainbird.com
NOTICE
Changes or modifications not expressly approved by Rain Bird could void the user's authority to operate the equipment.
NOTICE
Date and time are retained by a lithium battery which must be disposed of in accordance with local regulations.
NOTICE
Model, serial number, supply rate, manufacturing country and fabrication date are located on the back of the wiring bay cover.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capacity, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Stationary appliances not fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under overvoltage category III, the instructions state that means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules
Rain Bird ESP-TM2 on the Web
www.rainbird.com
wifi-pro.rainbird.com
Rain Bird Corporation
6991 East Southpoint Road
Tucson, AZ 85756
USA
Tel: (520) 741-6100
Rain Bird Corporation
970 West Sierra Madre Ave.
Azusa, CA 91702
USA
Tel: (626) 812-3400
Rain Bird International
1000 West Sierra Madre
Azusa, CA 91702
USA
Phone: (626) 963-9311
Technical Services for U.S. and Canada only:
1 (800) RAINBIRD
1-800-247-3782
www.rainbird.com
Specification Hotline U.S. and Canada only:
1 (800) 458-3005
© 2019 Rain Bird Corporation
® Registered trademark of Rain Bird Corporation
VideosRain Bird ESP-TM2 Controller: Manual Watering Options Video by Rain Bird
Rain Bird ESP-TM2 Controller: Basic Programming Video by Rain Bird
Rain Bird ESP-TM2 Controller: Advanced Programming Video by Rain Bird
Rain Bird ESP-TM2 Controller: Installation Video by Rain Bird
Documents / Resources
References
ESP-TM2 Series Controllers | Rain Bird
RainBird Services
YouTube
Rain Bird | A Global Irrigation Company
Download manual
Here you can download full pdf version of manual, it may contain additional safety instructions, warranty information, FCC rules, etc.
Download Rain Bird ESP-TM2 Manual